T2960

The SpecSeal® LC Endothermic Firestop Sealant | 4-Hr UL Rating

High-solids, latex-based endothermic firestop sealant for construction joints and penetrations —

tested to UL1479 / ASTM E814, UL2079 / ASTM E1966, and CAN/ULC-S115. Provides up to 4-hour
protection in tested systems with excellent smoke sealing and paintable finish.

endothermic firestop sealant
UL1479 firestop
CAN/ULC-S115
ASTM E814
joint firestopping
penetration firestop
non-halogenated
low VOC

Key Features & Benefits

  • Water-based, high-solids formula for easy installation and cleanup
  • Endothermic fillers absorb heat & release water for enhanced fire resistance
  • Up to 4-hour UL-classified fire rating in tested systems
  • Flexible, non-shrinking barrier with excellent smoke sealing
  • Adheres to concrete, masonry, gypsum, and steel
  • Non-halogenated, asbestos-free, low VOC; LEED compliant
  • Paintable finish; installer-friendly with high build capability
  • Red color for quick inspection and identification

Applications

  • Construction joint & gap sealing in walls and floors
  • Through-penetration firestopping of noncombustible penetrants (up to 30″ diameter)
  • Multiple penetrant firestopping in masonry and gypsum assemblies
  • Electrical & communications cable penetrations; steel-sleeved penetrations
  • Commercial, industrial, and institutional projects

Product Specifications

Color Deep Red
Density 10.7 lb/gal (1.28 kg/L)
Solids (by weight / volume) 81% / 75.2%
VOC Content 57 g/L
Movement Capability ±12.5% or 25% compression only
In-Service Temperature ≤ 185°F (85°C)
Application Temperature 35°F to 100°F (2°C to 38°C)
Shelf Life 24 months
Standards / Tests ASTM E814 (UL1479), ASTM E1966 (UL2079), CAN/ULC-S115

Always install per tested system details and manufacturer instructions.


Available Variants

Catalog No. Size & Volume Qty. Case Qty. Weight (Each)
LC150 10.1 oz Tube (300 ml) 1 12 0.96 lbs
LC120 20 oz Sausage (592 ml) 1 12 1.70 lbs
LC129 29 oz Tube (858 ml) 1 12 2.56 lbs
LC155 5 Gallon Pail (19 L) 1 1 55.81 lbs

Certifications & Test Standards

  • UL1479 / ASTM E814 — Fire Tests of Penetration Firestop Systems
  • UL2079 / ASTM E1966 — Fire-Resistive Joint Systems
  • CAN/ULC-S115 — Fire Tests of Firestop Systems
  • LEED v4.1 — Low-Emitting Materials credit eligible

FAQs

What is the fire rating?
Up to 4 hours when installed in tested systems per UL1479 / ASTM E814 and CAN/ULC-S115.
Can it be painted?
Yes. After full cure, the sealant is paintable for a clean finish.
Is it safe for occupied buildings?
Yes. It’s non-halogenated, asbestos-free, and low VOC.

Downloadable Resources

TDS
SDS