T2960

ROPES VEDAFEU C©

Product Overview

VEDAFEU C fire-rated backer rod consists of non-combustible, rot-proof mineral fibers embedded in a glass-fiber mesh.
Depending on its diameter, the rope has a specific density that makes it flexible and easy to compress.
Each piece is identified by exclusive markings to ensure the fire-stop seal installed is the one specified.


Key Specifications

  • Fire Rating: EI 240 (fire integrity and thermal insulation for 240 minutes)
  • Compression: Up to 80% compression capability
  • Expansion Movement: Up to 20% expansion accommodation
  • Joint Width: 10mm to 120mm gap coverage
  • Installation: Horizontal and vertical applications
  • Material: Non-combustible mineral fibers with glass-fiber mesh

Available Sizes & Applications

Reference Gap Up To (mm) Visible Width S (mm) Total Width B (mm) Height H (mm) Movement Range
VEDAFEU C12 10 10 12 12 +20% / -80%
VEDAFEU C20 12 12 20 20 +20% / -80%
VEDAFEU C30 20 20 30 30 +20% / -80%
VEDAFEU C40 25 25 40 40 +20% / -80%
VEDAFEU C50 30 30 50 50 +20% / -80%
VEDAFEU C60 40 40 60 60 +20% / -80%
VEDAFEU C80 50 50 80 80 +20% / -80%
VEDAFEU C90 60 60 90 90 +20% / -80%
VEDAFEU C100 65 65 90 90 +20% / -80%
VEDAFEU C120 80 80 120 120 +20% / -80%
VEDAFEU C150 100 100 150 150 +20% / -80%
VEDAFEU C170 110 110 170 170 +20% / -80%
VEDAFEU C180 120 120 180 180 +20% / -80%

Applications

This fire-rated rope can be used in all types of buildings: hospitals, industrial and office buildings, homes, hotels, shopping malls, parking lots, schools, colleges, stations, airports, and stadiums.

  • Expansion joints in floors, walls, and ceilings
  • Head-of-wall applications with special configurations
  • Fire partitions and conduit penetrations
  • Service ducts protection
  • Masonry edges sealing between floors and curtain walls

Key Performance Benefits

  • EI 240 Fire Rating: Maintains fire integrity and thermal insulation for 240 minutes
  • Movement Accommodation: Tested without sealant and supports +20% movement
  • High Compression: Withstands up to 80% compression capability
  • Easy Installation: Quick setup; a single fire cord is sufficient for expansion joints
  • Chemical Resistance: Resistant to water, humidity, aggressive chemicals, and micro-organisms
  • Unique Identification: Exclusive markings ensure correct installation